National Instruments software portfolio includes programming environments, application software, software add-ons, and software suites. 1553. Fast Quotes & Shipping. My hardware : PCI 4070, SCXI1000, 2 SCXI1127, SH9MD-AUX cable and SCXI 1359 kit. SCXI-1127 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. ¥Ifyou are using a PXI-1011 use an HV8-BAN4 cable. The SCXI-1362 Kit includes an SCXI-1362 backplane and an SH9MD-AUX cable. NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. This Terminal Block is designed solely for use with the National Instruments SCXI-1129 Multiplexer Switch. SCXI-1127 (300 V, CAT II) in Slot 4. National Instruments SCXI-1349 Adapter Board. Set the SCXI chassis address switch positions to the desired address. 8. 6. 1-slot adapters are sold separately. com 100-pin E Series DAQ device Two SCXI modules Note Refer to the Connections and Pin Assignments section for the SCXI modules that you can use with each 100-pin E Series DAQ device. You can control the SCXI-1169 with the PXI-6070E DAQ board, but you must configure a chassis under NI-DAQmx Devices. For example, NI DMMs and NI 4021 switch controllers require an NI SCXI-1359/1358/1357 adapter kit to connect to an NI SCXI switch module. SCXI-1359 2-slot backplane adapter behind Slots 3 and 4. . MXI / MXI-2 / MXI-3 / MXI-4. arincSee all Driver Software Downloads. The 185003A-01 is the 1-slot HVAB Adapter for SCXI chassis. 1553. USB-1357 kit, USB-1358 kit, USB-1359 kit, or NI. When using the Ni Switch SFP I am able to go to the relays tab and toggle relay positions open and closed, and I hear the relay actuating inside the switch. arincI'm having trouble getting readings from my PXI-4070 using SCXI-1127/1331 cards. The SCXI-1349 Cable Adapter joins a 68-pin E Series DAQ Device (minus the 61XXE models), to an SCXI module (except the SCXI switch modules). com for information on these kits. The SCXI-1359 is the 2-slot HVAB Adapter for SCXI chassis. I've used the sample pro. 6 NI SCXI-1359 Cable Adapter 7 NI SCXI-1000/1001 or NI PXI-1010 Chassis 1 7 6 or 4 5 3 2. Community. ). arinc I'm having trouble getting readings from my PXI-4070 using SCXI-1127/1331 cards. arincNI SCXI-1359 cable adapter and the other end to the NI 4021/4060/407x switch controller as shown in Figure 4. SCP. The SCXI kit connects a switch controller to an SCXI switch module; the USB kit connects a computer to an SCXI switch module. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Both the NI 1359 and SCXI-1362 provide NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. arincNational Instruments' USB-1359 Adapter: A Communication SolutionThe USB-1359 is a communication adapter developed by National Instruments, offering USB connectivity for SCXI switch modules. Notes If you are using NI-DAQmx to configure SCXI switch modules cabled to an NI SCXI-1357/1358/1359 kit, proceed directly to step 4 to create a new SCXI chassis. arincJason ApexWaves. arinc & 1553 . This High Voltage Backplane. Part Number: 776575-57, 185006A-01, 185006B-01. SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. More National Instruments Manuals . Do you have a HV8-BAN4 cable between the SCXI-1359 (connected to the back of the 1127) and the front of the DMM? Make sure AB0+ and AB0- are correctly connected to the DMM. Combining this 1-slot HVAB Adaptor with another 1-slot Adaptor creates and an SCXI-1359 2-slot HCAB create an SCXI-1357. arincThe National Instruments SCXI-1359 kit includes the NI SCXI-1357 high-voltage 2-slot backplane adapter and cable that connects the digital control lines of NI 407x DMMs, NI 4060 DMMs, or NI 4021 switch controllers to the SCXI-1127, SCXI-1128, SCXI-1129, SCXI-1130, SCXI-1166, SCXI-1167, and SCXI-1193 switch modules. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. SCParinc & 1553 . Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. Associated Part Numbers: 184366-01, 184366C-01, 184366D-01, 184366E-01, 776572-27. Other slot adapters are sold separately. Other Industrial. 1553. Site Search Results. 0 or earlier. SCXI-1127, SCXI-1331 (Figure 6) Multiplexer 777687-31 SCXI-1128 SCXI-1332 Matrix 777687-32. The National Instruments SCXI-1359 kit includes the NI SCXI-1357 high-voltage 2-slot backplane adapter and cable that connects the digital control lines of NI 407x DMMs, NI 4060 DMMs, or NI 4021 switch controllers to the SCXI-1127, SCXI-1128, SCXI-1129, SCXI-1130, SCXI-1166, SCXI-1167, and SCXI-1193 switch modules. 3. 1-slot adapters are sold separately. arinc2-Slot, High-Voltage SCXI Connector. you can communicate with all SCXI modules containing a 10-pin rear connector,while the SCXI-1362 provides connectivity to all modules containing a 50-pin rear connector. 1553. Incubators / Ovens / Hybridizationarinc & 1553 . Select a unique address for each chassis in the system. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. . arinc2. 1553. For the SCXI-1130, you only need a communication adapter, so the SCXI-1359 or USB-1359 are appropriate options. com today Toggle navigation ({{ cartItems. Site Search Results. 1553. SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. However, parts are committed on a first come first serve basis. com today. This unit ships in the opened National Instruments box. manualslib. 1553. The SCXI-1357 has a 10-pin rear connector. The USB-1359 is compatible with two cables, the 1 m HV8-BAN4 cable and the 2 m HV8-BAN4 cable. We currently maintain an inventory with a wide array of components. Both the NI USB-1359 and NI SCXI-1359. 1553. 2. At the time we were pressed for a test solution at budgeted price (which was not a lot) and so we took the idea along with any white papers to present to our management. MXI / MXI-2 / MXI-3 / MXI-4. 1553. 1553. 4. ¥Ifyou are using a PXI-1011 use an HV8-BAN4 cable. Figure 4. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Includes: Adapter and installation guide. Figure 4. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. 776575-59 National Instruments national instruments 776575-59 scxi-1359 2-slot communication backplane onlyWith the National Instruments USB-1359. ni scxiスイッチモジュールにはni-switch 計測器ドライバ が同梱されており、このドライバはデバイスのプログラミングに使用します。 このドキュメントには、NI スイッチモジュールのプログラミングにも使用できるNI-The SCXI-1169 is a DAQmx-only device. The SCXI kit connects a switch controller to an SCXI switch module; the USB kit connects a computer to an SCXI switch module. This Switch Controller is less expensive than other models and provides suitable control elucidation for switching. 3. cable is available in lengths of 1, 2, 5, and 10 m. arincIt is practical to mix SCXI and PXI. Log on to ni. Connect the DAQ device to a different computer or PXI controller slot, module or USB port. I know this is a little used controller for the SCXI-1000 chassis, but the fact is my company has three of these and other than Windows 32-bit computer obsolescence we have no reason to upgrade. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Therefore, the NI SCXI-1. SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a. 1553. 5. Control Unit I/O Systems Controller Computer Hardware Measuring Instruments. Within the SCXI chassis, identify the appropriate SCXI module to connect to the cable adapter. Make sure the E/M/X Series DAQ device is recognized by the operating system, is found in MAX, and passes the resource test. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. When using a DMM or NI 4021 switch controller to communicate with SCXI switches, use the SCXI-1359 communication adapter as an. Share your list with your colleagues. Figure 4. 1359 Slater St , Victoria, BC V8X2P is currently not for sale. Particle Sizers / Counters2. arinc & 1553 . Page 2 SCXI Controller/Adapter Kit ™ This document describes the components, installation, and configuration of the National Instruments SCXI-1357/1358/1359 and the NI USB-1357/1358/1359 controller/adapter kits. Explore a wide range of support content, including. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. This Communication Adapter directly links to modules with 10-pin back connectors via the use of a cable. The SCXI-1359 is the 2-slot HVAB Adapter for SCXI chassis. 3. The SCXI-1362 Kit includes an SCXI-1362 backplane and an SH9MD-AUX cable. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. 2-Slot, High-Voltage SCXI Connector. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Particle Sizers / Counters2-Slot, High-Voltage SCXI Connector. 1553. SCXI-1346 Shielded Multichassis Cable Adapter 2 ni. Remove the filler panel from an unused SCXI slot. 1553. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. com or CALL 800 813 3693 (U. National Instruments SCXI-1359 2-Slot High Voltage Backplane Adaptor. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. NI-DAQmx. Then, follow the steps below: 1. SCXI-1303 Terminal Block The cable HV8-BAN4 is used to connect SCXI backplanes to an NI DMM. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Single module information can be found in the NI. arincEmbedded & Industrial . NI SCXI-1359 cable adapter and the other end to the NI 4021/4060/407x switch controller as shown in Figure 4. Some SCXI switches can route analog signals to their rear connector, and you can use the SCXI-1359 to share these signals among several modules in compatible chassis. All specifications are subject to change without notice. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. The NI USB-1359 also offers USB connectivity for simple plug-and-play setup of a switch chassis. ATG Resources . ¥Ifyou are using a PXI-1010 or an SCXI chassis use an SCXI-1357 or SCXI-1359 kit. SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a. 50-Pin Rear Connector You must determine the number of pins on the rear connector of your NI SCXI switch module to choose the appropriate set of steps to cable the switch controller to the switch module. Power off and unplug the chassis. NI 1357/1358/1359 SCXI Controller/Adapter Kit This document describes the components, installation, and configuration of the National Instruments SCXI-1357/1358/1359 and the NI USB-1357/1358/1359 controller/adapter kits. 3. Proceed to the. 1. a switch controller to an SCXI switch module; the USB kit connects a. SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a. 1–5, 7–9. 1553. Alternatively, a switch controller installed in the. Reinstall the strain-relief bar and tighten the strain-relief screws. scxiスイッチはsh9md-auxケーブルとの接続にバックプレーンアダプタが必要です。バックプレーンはsh9md-auxから、バックプレーンの最も右側にあるスイッチの背面へ信号を経路設定します。 NI 1357/1358/1359 SCXI Controller/Adapter Kit This document describes the components, installation, and configuration of the National Instruments SCXI-1357/1358/1359 and the NI USB-1357/1358/1359 controller/adapter kits. Launch NI-DAQmx from the Start menu, or for. 1553. Boishakhi Cultural Program Hosted By Victoria Bengali Cultural Society. This has two High Voltage Analog Bus (HVAB) ports. ni scxiスイッチモジュールにはni-switch 計測器ドライバ が同梱されており、このドライバはデバイスのプログラミングに使用します。 このドキュメントには、NI スイッチモジュールのプログラミングにも使用できるNI- The SCXI-1169 is a DAQmx-only device. Site Search Results. The SCXI kit connects a switch controller to an SCXI switch module; the USB kit connects a computer to an SCXI switch module. you can communicate with all SCXI modules containing a 10-pin rear connector. 3. Find the National Instruments SCXI-1335 at our website: Click HERE. Readers should have a basic knowledge of single module scanning hardware setup and programming. National Instruments offers switches with scanning capabilities. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. ARINC. 2. Cabling an NI 4021/4060/407x Switch Controller to a 10-Pin Rear Connector Switch Module hc t i w SI X1SC 2 HVAB Connector 3 10-Pin Rear Connector 4 SH9MD-AUX CableThe National Instruments SCXI-1357 High Voltage Backplane Adapter functions with a maximum current of 2 ADC, 2 AAC per channel. You could also have some other type of controlling device for the SCXI chassis. Alternatively, a switch controller installed in the. 11-26-2022 09:55 AM - edited 11-26-2022 09:56 AM. NI SCXI-1331 Installation Instructions 8 ni. arincThe NI SCXI 1001 can also synchronize the timing between the DAQ device and each module. SCXI-1127 (300 V, CAT II) in Slot 4. The three available backplane kits are: SCXI-1357, SCXI-1358, and or SCXI-1359. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. To use the HVAB connectors on the NI 1357/1358/1359 kit, unscrew and flip back the covers. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. National Instruments offers switches with scanning capabilities. Save products while you explore the catalog. arinc & 1553 . Existing Controller. Buying SCXI chassis was an idea offered by National Instrument sales rep. NATIONAL INSTRUMENTS CORP. com Figure 9. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. NI SCXI-1359 cable adapter and the other end to the NI 4021/4060/407x switch controller as shown in Figure 4. 343159 × 10–4, c = 1. National Instruments 185003A-01 1-Slot High Voltage Backplane AdaptorThe 185003A-01 is the 1-slot HVAB Adapter for SCXI chassis. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Please refer to the NI Switches Getting Started Guide for. Part Number: 776575-57, 185006A-01, 185006B-01, 185008A-01, 185008B-01 † For devices cabled to an NI SCXI-1357/1358/1359 kit, proceed to step 3. Alternatively, a switch controller installed in the. The cable HV8-BAN4 is used to connect SCXI backplanes to an NI DMM. Alternatively, a switch controller installed in the rightmost PXI slot of an USB-1358 kit, NI SCXI-1349 and NI SCXI-1358 USB-1359 kit, either NI SCXI-1129 kit, or or NI SH-68-68-EPM (NI NI SCXI-1130 NI SCXI-1359 SCXI-1600 E Series or mass- terminated All other Modules NI USB MSeries) or SHC68-68-EPM (NI PXI/PCI M Series) An NI E or M Series device can control these switches when cabled to any 50-pin rear connector NI. If a compatible driver version has been already installed, try reinstalling the driver. arinc & 1553 . Page 11 SCXI-1359. This document contains information about the NI-DAQmx driver software, which you canSCXI Chassis Connector—The USB-1359 communication adapter provides several options for communication with and expansion of the functionality of your SCXI switch chassis. Other slot adapters are sold separately. Do you have a HV8-BAN4 cable between the SCXI-1359 (connected to the back of the 1127) and the front of the DMM? Make sure AB0+ and AB0- are correctly connected to the DMM. . Unscrew the top cover screws and remove the cover. For that: In Windows Device Manager, right-click on. SCXI-1317 Circuit Parts Location Diagram 6. Refer to the SCXI Quick Start Guide to determine the appropriate module. Page 9 Select NI-DAQmx SCXI Chassis, and choose the chassis. My hardware : PCI 4070, SCXI1000, 2 SCXI1127, SH9MD-AUX cable and SCXI 1359 kit. Insert the switch module into the SCXI slot. Cabling an NI 4021/4060/407x Switch Controller to a 10-Pin Rear Connector Switch Module hc t i w SI X1SC 2 HVAB Connector 3 10-Pin Rear Connector 4 SH9MD-AUX Cable 5 NI 4021/4060/407x 6 NI SCXI-1359 The National Instruments SCXI-1357 High Voltage Backplane Adapter functions with a maximum current of 2 ADC, 2 AAC per channel. Topologies 2-wire 16 × 16 matrix 2-wire 4 × 64 matrix 2-wire 8 × 32 matrix 2-wire quad 4 × 16 matrix 2-wire dual 4 × 32 matrix 2-sire dual 8 × 16 matrixProducts from SCXI. SCXI-1000 chassis. National Instruments - National Instruments provides powerful, flexible technology solutions that accelerate productivity and drive rapid innovation. This has two High Voltage Analog Bus (HVAB) ports. With the NI 1359. Fieldpoint / CompactFieldpointarinc & 1553 . If you are usingSCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. lang:fr score:38 filesize: 1. arinc & 1553 . 1553. 1. Choosing a Switch Controller SCXI Controller Rear Connector Switch Module NI 4021 NI 4060 1 PXI-4070 E Series 10-pin SCXI-1127 SCXI-1359 Kit SCXI-1357 Kit SCXI-1357 Kit Can ControlDrives / Motion / Motor Control / Positioning. 1. 1553. 1. Begin with all three SCXI chassis powered off and unplugged. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Leave jumper W1 on the SCXI-1100 in the factory-default (parking) position. National Instruments offers switches with scanning capabilities. MXI / MXI-2 / MXI-3 / MXI-4Site Search Results. arincAmphenol Cables on Demand Amphenol CS-DSDMDB09MF-002. 1553. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. 3. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Single module information can be found in the NI. arincarinc & 1553 . I have (4) SCXI-1127 cards in a chassis. 1553. are not included with this equipment unless listed in the above stock item description. 1553. Email: info@artisantg. 295361 × 10–3, b = 2. The. . Figure 5 : Rear view of SCXI. National Instruments SCXI-1359 2-Slot High Voltage Backplane Adaptor. Rear of SCXI-1346 Note The SCXI-1346 covers the rear connector of two modules. 0 in. 1553. The SCXI-1359 includes an SCXI-1359 backplane and an SH9MD-AUX cable. Readers should have a basic knowledge of single module scanning hardware setup and programming. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Alternatively, a switch controller installed in the. First, on the front panel, there is a 68-pin male connector. Other Industrial. 5 9-Pin (DB9) Deluxe D-Sub Cable - Copper Shielded - Male / Female 2. Part Number: 776575-581, 776575-582 Show More Description Important Notice: Other accessories, manuals, cables, calibration data, software, etc. 0. The SCXI-1127 weighs 1 lb, and has the dimensions: 1. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. SH1006868 cable, an SCXI-1349 shielded cable adapter, and an. NI SCXI-1359 (2-slot HVAB backplane adapter with 9-pin DIN connector) SH9MD-9MD cable (SCXI kits) or USB cable (USB kits) The NI 1358 kit (12 slots) consists of the. 3. Particle Sizers / CountersEmbedded & Industrial . Figure 4. View online (12 pages) or download PDF (1 MB) National Instruments SCXI NI 1359, SCXI NI 1358 Installation manual • SCXI NI 1359, SCXI NI 1358 PDF manual download and more National Instruments online manualsSCXI Communication Adapter Kits These kits include a backplane adapter that connects the digital control lines of the NI 4060 and PXI-4070 DMMs and NI 4021 switch controller to the switch modules. SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. TypeNational Instruments offers switches with scanning capabilities. Alternatively, a switch controller installed in the. Modules Terminal Block Description Part Number SCXI-1127, SCXI-1331 (Figure 6) Multiplexer 777687-31. Add to Cart. The 185003A-01 is the 1-slot HVAB Adapter for SCXI chassis. arincProducts from Manufacturer: Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. TypeSite Search Results. Fast shipping. 1553. Texas Instruments 32-Bit, 33 MHz PCI-to-PCI Bridge, Compact PCI Hot-Swap Friendly, 4-Master 160-QFP 0 to 70Embedded & Industrial . Alternatively, a switch controller installed in the. 1553. Product Support Resources. NI 1357/1358/1359 SCXI Controller/Adapter Kit This document describes the components, installation, and configuration of the National Instruments SCXI-1357/1358/1359 and the NI USB-1357/1358/1359 controller/adapter kits. The computer/controller is a PXI-8175 with Win2000. I am attaching the Datasheet and here is a link to the product help that explains how to make the connections to measure resistance. SCXI-1001: PXIe-1065: cDAQ 9178 cDAQ. SCXI Communication. in 2005. This model implements an advanced switching system, which is based on SCXI technology and does not need any other software. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Alternatively, a switch controller installed in the rightmost PXI slot of anUSB-1358 kit, NI SCXI-1349 and NI SCXI-1358 USB-1359 kit, either NI SCXI-1129 kit, or or NI SH-68-68-EPM (NI NI SCXI-1130 NI SCXI-1359 SCXI-1600 E Series or mass- terminated All other Modules NI USB MSeries) or SHC68-68-EPM (NI PXI/PCI M Series) An NI E or M Series device can control these switches when cabled to any 50-pin rear connector NI. Visit ni. SCXI-1325 for the appropriate module, as indicated in Figure 2. Quick Start Guide Installation Guide Guide Archived NI 1357 1358 1359 SCXI Controller Adapter Kit Installation Guide National Instruments 374133 324133 Technical Communications 374133c ni support compware manuals ||| INSTALLATION GUIDE NI 1357/1358/1359 SCXITM Controller/Adapter Kit Introduction This document describes. The SH1006868 cable. The SCXI-1358 consists of (2) 1-slot HVAB Adapters, (1) SCXI-1359 2-slot HVAB Adapter and (1) 8-Slot HVAB Adapter. Screw the backplane adapter to the chassis mounting rail. Manuals. Reinstall the top cover and tighten the top cover screws. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. For example, DMMs and NI 4021 switch controllers require an NI SCXI-1359/1358/1357 adapter kit to connect to an SCXI switch module. arincarinc & 1553 . arincarinc & 1553 . National Instruments USB-1359 2-Slot High Voltage Backplane Adaptor for USB Manuals, Datasheets, Drivers, Links NI SCXI-1359 cable adapter and the other end to the NI 4021/4060/407x switch controller as shown in Figure 4. Students in our Earth Sciences. in 2005. For the SCXI-1130, you only need a communication adapter, so the SCXI-1359 or USB-1359 are appropriate options. 3. In a multi-module scanning, only one SCXI switch needs to. Log on to ni. SCXI Model Number: PXI Model Number: C Series Model Number SCXI-1000: PXIe-1071: cDAQ 9174 cDAQ 9184 SCXI-1000DC: PXIe-1071 PXIe-1082 (782946-01) cDAQ 9174 cDAQ 9184: Choose the PXIe-1071 if the application requires four PXIe slots; however, if DC power is a more important feature choose the PXIe-1082 (DC). Alternatively, a switch controller installed in the. See Table 1 for more information on applicable modules. Page 9 Select NI-DAQmx SCXI Chassis, and choose the chassis. Part Number: 185003A-01 . arincSCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. Our Studica Robotics line offers hundreds of parts, including mechanical structures, motion components, and electronics that are used in the classroom for teaching, competitions, and are also utilized in industry. SCXI-1314 Shunt-Calibration Resistors and Quarter-Bridge Resistors R1 RPJ R2 R3 UJ SCB SCB SCB SCB SCA SCA SCA SCA QTR QTR. Combining this 2-slot HVAB Adaptor with (2) 1-slot Adaptor creates an SCXI-1357. Control Systems / PLC You also need a backplane adapter for controlling the SCXI module. With the NI 1359. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. † For devices cabled to an NI USB-1357/1358/1359 kit, where the NI USB-1359 is auto-detected and the chassis is auto-created in MAX as shown in Figure 10, complete the Parts List makes it easier to research and evaluate products on ni. SCXI-1190 (30 V, CAT I) in Slot 3. MXI / MXI-2 / MXI-3 / MXI-4. computer to an SCXI switch module. Fast shipping. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The NI SCXI 1195 quad 4x1 switch shows up correctly in the NI SCXI-1001 switch box under the NI-DAQmx Devices pane of MAX ver 4. Page 2 SCXI Controller/Adapter Kit ™ This document describes the components, installation, and configuration of the National Instruments SCXI-1357/1358/1359 and the NI USB-1357/1358/1359 controller/adapter kits. MXI / MXI-2 / MXI-3 / MXI-4. com.